my newest cannon

Boom! The classic potato gun harnesses the combustion of flammable vapor. Show us your combustion spud gun and discuss fuels, ratios, safety, ignition systems, tools, and more.
larsul
Recruit
Recruit
Posts: 1
Joined: Thu Dec 27, 2007 4:25 pm

Mon Jan 07, 2008 9:41 pm

as a kid i always toyed around with the basic combustion cannon, nothing special. but after discovering spud files a few weeks back and seeing where these things have gone over the years i knew i had to build a bigger and better one

it consists of
metered propane injection, meter pipe is cut exactly to length to get a perfect 4.02% in my chamber (@ 90psi)
dual ignition via bbq grill ignitor
80mm pc chamber fan powered by a nine volt and a momentary switch mounted on the forward grip
so far the thing has been working great, fires every time. i had at first started to paint it but after scratching the hell out of the paint during assembly i decided to just get it together and worry about paint when the summer gets here
Attachments
DSCN0834.JPG
DSCN0837.JPG
DSCN0836.JPG
Last edited by larsul on Tue Jan 08, 2008 5:07 pm, edited 4 times in total.
User avatar
Ragnarok
Captain
Captain
Posts: 5401
Joined: Tue Dec 19, 2006 8:23 am
Location: The UK

Mon Jan 07, 2008 9:45 pm

You do need pictures to go in the showcase. It sounds good, but I'd like to see that myself.

I should also point out that the perfect propane percentage is 4.19%, not 4.02% or 4.03% - which I see hanging around a lot.
Does that thing kinda look like a big cat to you?
User avatar
SpudUke5
Sergeant
Sergeant
Posts: 1099
Joined: Tue Sep 04, 2007 10:16 pm

Tue Jan 08, 2008 12:43 am

Then that should be fixed in the wiki and the stiociometric calcultions should be redone
4SPC, My 4" piston 3" porting cannon
Memo:
Fix up copper cannon
Fix up 4SPC
Start Stirrup pump
Start Toolies piston bazooka
User avatar
Hubb
First Sergeant 2
First Sergeant 2
Posts: 2390
Joined: Mon May 28, 2007 8:39 am
Location: South Georgia
Contact:

Tue Jan 08, 2008 10:47 am

Spudfiles Wiki wrote:The actual percentage of fuel for a stoichiometric mixture will depend on whether the fuel is added to the air in the chamber or the fuel displaces some of the air in the chamber. If the fuel is added to the air in the chamber then the fuel volume is 4.2% of the chamber volume. If the fuel displaces some of the air in the chamber then the fuel volume is 4.02% of the chamber volume.

Most fuel meters do not displace air in the chamber with fuel (the pressure in the chamber rises slightly when the fuel is injected), so for a meter the fuel volume is 4.2% of the chamber volume. If the fuel is injected with a syringe, and the fuel displaces some of the air in the chamber, then the fuel volume should be 4.02% of the chamber volume.
It's already in the Wiki and can be found here.
User avatar
STHORNE
Sergeant 3
Sergeant 3
Posts: 1208
Joined: Wed Feb 14, 2007 7:50 pm
Location: Kewaunee, Wisconsin

Donating Members

Sat Jan 19, 2008 10:33 pm

wow......... very nice gun. pretty clean and not to complicated, i like it.
User avatar
SpudFarm
First Sergeant 3
First Sergeant 3
Posts: 2571
Joined: Sat Nov 04, 2006 9:39 am
Location: Norway Trondheim area

Donating Members

Sun Jan 20, 2008 2:08 pm

pretty old topic but can you tell what size the chamber and barrel are?
User avatar
mark.f
Sergeant Major 4
Sergeant Major 4
Eritrea
Posts: 3638
Joined: Sat May 06, 2006 11:18 am
Location: The Big Steezy
Has thanked: 58 times
Been thanked: 60 times
Contact:

Donating Members

Mon Jan 21, 2008 5:58 pm

Ragnarok wrote: I should also point out that the perfect propane percentage is 4.19%, not 4.02% or 4.03% - which I see hanging around a lot.
Actually, I would like to point out that both are correct. :wink: For an injection system which injects propane into a closed chamber, (i.e. the gas displaces no air from the chamber), 4.2% is the correct percentage. For an injection system which displaces air as it injects gas, 4.03% is the correct ratio to use in you calculations to simplify things, instead of having to solve a linear system of equations to get the correct meter pressure.