33/64" fitting question

Show us your pneumatic spud gun! Discuss pneumatic (compressed gas) powered potato guns and related accessories. Valve types, actuation, pipe, materials, fittings, compressors, safety, gas choices, and more.
squnto
Private
Private
Posts: 6
Joined: Sat Dec 24, 2011 10:53 pm

Sat Dec 24, 2011 10:54 pm

will this slide valve:

http://www.ebay.com/itm/33-64-Pneumatic ... 5ae3de3c4c

fit into a standing 1/2" fitting? The difference is so small that it just might work...

thanks in advance!
User avatar
JDP12
Staff Sergeant 5
Staff Sergeant 5
Posts: 1943
Joined: Fri Mar 30, 2007 8:34 pm

Sat Dec 24, 2011 11:10 pm

it's equivalent to 1/4" BSPP thread.
"Some say his pet elephant is pink, and that he has no understanding of "PG rated forum". All we know is, he's called JSR. "
squnto
Private
Private
Posts: 6
Joined: Sat Dec 24, 2011 10:53 pm

Sat Dec 24, 2011 11:16 pm

American fittings are npt, correct? is bspp at all compatible with npt fittings, or would i have to buy some crazy ass fitting to bridge the two?
User avatar
JDP12
Staff Sergeant 5
Staff Sergeant 5
Posts: 1943
Joined: Fri Mar 30, 2007 8:34 pm

Sat Dec 24, 2011 11:23 pm

ya america typically uses NPT. BSPP and NPT are NOT COMPATIBLE. you will have to get an adapter- www.mcmaster.com sells them.
"Some say his pet elephant is pink, and that he has no understanding of "PG rated forum". All we know is, he's called JSR. "
squnto
Private
Private
Posts: 6
Joined: Sat Dec 24, 2011 10:53 pm

Sat Dec 24, 2011 11:39 pm

thanks mate :)

workin on an all metal semi auto marble gun that this'll be lush for!
User avatar
MrCrowley
Moderator
Moderator
Posts: 10078
Joined: Fri Jun 23, 2006 10:42 pm
Location: Auckland, New Zealand
Been thanked: 3 times

Sun Dec 25, 2011 1:22 am

JDP12 wrote:ya america typically uses NPT. BSPP and NPT are NOT COMPATIBLE. you will have to get an adapter- www.mcmaster.com sells them.
Well they thread together, you might need to use a bit more teflon tape than usual to get them to seal. At high pressures, epoxy or thread seal may be required for a seal.
User avatar
JDP12
Staff Sergeant 5
Staff Sergeant 5
Posts: 1943
Joined: Fri Mar 30, 2007 8:34 pm

Sun Dec 25, 2011 1:39 am

yes... however the threads on that slide valve are BSPP, so they are parallel threads, whereas NPT are tapered. personally I'd recommend just getting the adapter, as i hate jury-rigging threaded fittings. just my 2 cents.
"Some say his pet elephant is pink, and that he has no understanding of "PG rated forum". All we know is, he's called JSR. "
Post Reply