3/2 valve as main valve?

Building or modifying BB, Airsoft, and Pellet type of guns. Show off your custom designs, find tips and other discussion. Target practice only!
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Fri Feb 10, 2012 3:50 pm

I found that Clippard makes solenoid valves, and here is the selection page

http://www.clippard.com/store/byo_maximatic/byo_ev.asp

one thing I want to get clear is should I choose direct acting spring return, or electronic piloted spring return?

if I choose electronic piloted spring return I get this
http://www.clippard.com/store/display_d ... 32QES-W012#

if direct acting spring return I get this
http://www.clippard.com/store/display_d ... -3QDS-D012#

On a side note, what is gourmet for wire attachment?
User avatar
Gun Freak
Lieutenant 5
Lieutenant 5
Posts: 4971
Joined: Mon Jan 25, 2010 4:38 pm
Location: Florida
Been thanked: 8 times

Fri Feb 10, 2012 6:03 pm

Clippard is ridiculously expensive plus they nail you on shipping AND handling, which is about 20 bucks extra.
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna"M16 BBMGPengunHammer Valve Airsoft SniperHigh Pressure .22 Coax
Holy Shat!
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Fri Feb 10, 2012 6:24 pm

one thing I want to get clear is should I choose direct acting spring return, or electronic piloted spring return?
you want an indirect acting valve... that's electronic piloted spring return
Children are the future

unless we stop them now
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Fri Feb 10, 2012 8:58 pm

Sorry Poland, I'm really not sure what all these different terms mean.

If I'm understand correctly, an indirect acting solenoid uses the solenoid to pilot a small valve, which in turn move the spool to a different position. And a direct acting solenoid valve uses the solenoid itself to move the spool.

Now, what does electronic piloted mean? I thought it meant the same as indirect acting solenoid...
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Fri Feb 10, 2012 9:26 pm

If I'm understand correctly, an indirect acting solenoid uses the solenoid to pilot a small valve, which in turn move the spool to a different position. And a direct acting solenoid valve uses the solenoid itself to move the spool.
yes, you understand it correctly
Now, what does electronic piloted mean? I thought it meant the same as indirect acting solenoid...
what is a pilot valve? it's a valve that opens a larger valve... the term electronic piloted valve basically means the same as indirect acting solenoid valve

Children are the future

unless we stop them now
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Fri Feb 10, 2012 10:57 pm

Thanks Poland, now everything is clear

Gun Freak wrote:Clippard is ridiculously expensive plus they nail you on shipping AND handling, which is about 20 bucks extra.
Yea, the valve itself is $26, but Clippard adds another $17 for shipping and handling, lol

Looks like I'm stuck with Clippard for this one, really can't find another 3/2 indirect acting solenoid valve for cleaper
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Sat Feb 11, 2012 6:29 am

well what about this one?? http://www.ebay.com/itm/3V210-08-DC-24V ... 5ae4a848c0

15$ + 2$ shipping
Children are the future

unless we stop them now
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Sat Feb 11, 2012 8:11 am

well what about this one??
I looked at that one before, it's normally closed, and it's 24v.

Ideally it should be 12v NO.

But then again, I could just put 2 3cell lipo in series, and that will give me 22.2 v

edit:

is it me or a lot of model numbers on ebay are not complete? Like the link poland posted, the model number should say NO or NC, also the thread dimentions
Last edited by bookyle on Sat Feb 11, 2012 8:51 am, edited 1 time in total.
User avatar
Jimmy K
Specialist
Specialist
Posts: 173
Joined: Wed Jan 20, 2010 9:17 pm

Sat Feb 11, 2012 8:36 am

I bought mine here:

http://www.automationdirect.com/adc/Sho ... id_Valves/

They will have much much faster processing and shipping - Same day shipping with FedEx for about $5. The total for me was about $32 (I got it the next day, too). Plus they're based in the US (Atlanta) and have a great tech support team.
ROLL TIDE ROLL
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Sat Feb 11, 2012 10:48 am

Is there any way to convert a normally closed valve to a normally open one?

Either of these two valves are good, but they are both normally closed.

http://www.automationdirect.com/adc/Sho ... S-3212-24D

http://www.ebay.com/itm/3V210-08-DC-24V ... 5ae4a848c0

Can the conversion be done? Or is it just too difficult to be practical?
User avatar
POLAND_SPUD
Captain
Captain
Posts: 5402
Joined: Sat Oct 13, 2007 4:43 pm
Been thanked: 1 time

Sat Feb 11, 2012 10:53 am

I looked at that one before, it's normally closed, and it's 24v.
the symbol suggests it is a NO valve... the box on the right is the normal position... there is an arrow from P (air source) to A (the port where you attach the barrel in a QEV + 3 way combo or, in your case, the chamber)

it's up to you to decide whether it's better to pay more
Children are the future

unless we stop them now
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Sat Feb 11, 2012 11:03 am

POLAND_SPUD wrote:the symbol suggests it is a NO valve...
Wait what? On the manufacture website, is the symbol flipped over? Or it's just that I can't understand those symbols?

http://en.airtac.com/pro_det.aspx?c_kin ... 5=77&id=47


edit

is the box on the right always the normal position? If that's the case, I'm reading everything wrong...

edit 2

the picture of the valve on the manufacture website has the same symbol on it, and on the valve it said NC
Last edited by bookyle on Sat Feb 11, 2012 11:14 am, edited 1 time in total.
User avatar
Gun Freak
Lieutenant 5
Lieutenant 5
Posts: 4971
Joined: Mon Jan 25, 2010 4:38 pm
Location: Florida
Been thanked: 8 times

Sat Feb 11, 2012 11:13 am

Why would you go through all this trouble and money to use a poor main valve? An electric 3-way isn't exactly optimum.
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna"M16 BBMGPengunHammer Valve Airsoft SniperHigh Pressure .22 Coax
Holy Shat!
bookyle
Private 4
Private 4
Posts: 61
Joined: Mon Dec 05, 2011 6:43 pm

Sat Feb 11, 2012 11:22 am

Gun Freak wrote:Why would you go through all this trouble and money to use a poor main valve? An electric 3-way isn't exactly optimum.
then what should I use?

I don't want to use a qev+3way because of the wasted pilot air, and the noise from the pilot

Can't really use a piston valve, because I can't think of a way for it to fit inside my airsoft boltaction rifle

What would be optimum if I want to fit the valve and the actuation mechanism to fit inside the receiver of an airsoft gun? I'm using regulated co2 as the air source.
User avatar
Gun Freak
Lieutenant 5
Lieutenant 5
Posts: 4971
Joined: Mon Jan 25, 2010 4:38 pm
Location: Florida
Been thanked: 8 times

Sat Feb 11, 2012 11:30 am

I didn't know you wanted it to fit in the small space. For that purpose, I suppose it will work. I still think it's ridiculously expensive though...

What about a mechanically actuated:
http://www.ebay.com/itm/Pneumatic-valve ... 45fe3000cd
OG Anti-Hybrid
One man's trash is a true Spudder's treasure!
Golf Ball Cannon "Superna"M16 BBMGPengunHammer Valve Airsoft SniperHigh Pressure .22 Coax
Holy Shat!