Hi all,
New to the forum and to homemade air guns. I want to build an HPA pellet rifle using a QEV. Want to test a basic setup then hopefully a semi/full auto.
I have found a HP hydraulic QEV that can handle well over 3000psi. I have some questions though:
1. does the qev chamber see all HP from the tank? Or should it be regulated to...?psi
2. will hydrualic valve work as pneumatic?
3. if the qev sees this HP, what kind of pilot/trigger valve will hold up?
4. Is it safe to use brass fittings or should I go with ss fittings?
These might be dumb q's but just want to be safe testing this!
Thanks
HPA + QEV pellet rifle q's
- jackssmirkingrevenge
- Five Star General
- Posts: 26203
- Joined: Thu Mar 15, 2007 11:28 pm
- Has thanked: 569 times
- Been thanked: 344 times
Show us the valve make, model, specs?
hectmarr wrote:You have to make many weapons, because this field is long and short life
Ruelco model RQ-2 1/2" NPT Hydraulic Quick Exhaust
there are different springs for various pressure ranges. Here's the link:
http://www.ruelco.com/product.php?pid=30
I don't know too much about valves, but maybe Ruelco has a valve that can be used as a pilot... if the pilot sees 2000+ psi (question 3 from above).
there are different springs for various pressure ranges. Here's the link:
http://www.ruelco.com/product.php?pid=30
I don't know too much about valves, but maybe Ruelco has a valve that can be used as a pilot... if the pilot sees 2000+ psi (question 3 from above).
- Lockednloaded
- Staff Sergeant
- Posts: 1566
- Joined: Thu Sep 03, 2009 9:38 pm
- Location: Texas, USA
- Been thanked: 7 times
I've looked at similar valves before, but you always need to be extra careful about hydraulic valves because they're not made for air. As for your pilot valve, a paintball slide valve can handle 2000 psi pretty well in my experience
I love lamp
Thanks. What would be possible problems? Leaking seals or nonoperation? With 3 springs to choose I thought I could try higher/lower rated spring compared to actual psi considering it's air and not liquid.Lockednloaded wrote:I've looked at similar valves before, but you always need to be extra careful about hydraulic valves because they're not made for air. As for your pilot valve, a paintball slide valve can handle 2000 psi pretty well in my experience
Has anyone tried hydraulic qev's?
-
- Specialist 3
- Posts: 343
- Joined: Thu Feb 16, 2012 5:23 pm
- Location: Leesburg
- Contact:
I WANT ONE OF THOSE VALVES! lol
how much are they?
how much are they?
- Crna Legija
- First Sergeant 2
- Posts: 2333
- Joined: Sun Jul 20, 2008 5:14 am
- Location: australia
might not seal at low pressure the piston might have a loose tolerance to allow oil to flow around it easier