does anyone know what what kind of connection i need for a Fire extinguisher tank? its internal size is 28,5 mm the outside is 33,5 mm here's a pic
- Labtecpower
- Sergeant 3
- Posts: 1297
- Joined: Sat Feb 20, 2010 6:38 am
- Location: Pyongyang
- Has thanked: 5 times
- Been thanked: 13 times
Kan je een foto maken van de data op de voorkant?
- Crna Legija
- First Sergeant 2
- Posts: 2333
- Joined: Sun Jul 20, 2008 5:14 am
- Location: australia
take it to a hardware store and just test witch fitting fits best, my one was very close to 1/2'' bsp so i just epoxied a 1/2 male fitting in there.
i have tested it to 600psi/41 bar
i have tested it to 600psi/41 bar
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
yes i have itMRR wrote:Do you still have the original plug that came with the fire extinguisher?
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
ja hoorLabtecpower wrote:Kan je een foto maken van de data op de voorkant?
The pipe that reaches from the plug to the bottom of the fe is screwed into it, try if a fitting fits with the threads. If so, cut away the original release valve from the plug and screw the fitting into it from the top.
It worked with my fire extinguisher but there will be some bottlenecking due to the smaller fitting.
It worked with my fire extinguisher but there will be some bottlenecking due to the smaller fitting.
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
will not work well its only from plastic ill think i will epoxy a 22 mm connection in it thanks Crna Legija and thank you all you helpt me get closer to the semi auto qev gunMRR wrote:The pipe that reaches from the plug to the bottom of the fe is screwed into it, try if a fitting fits with the threads. If so, cut away the original release valve from the plug and screw the fitting into it from the top.
It worked with my fire extinguisher but there will be some bottlenecking due to the smaller fitting.
- Crna Legija
- First Sergeant 2
- Posts: 2333
- Joined: Sun Jul 20, 2008 5:14 am
- Location: australia
if thats not a co2 fire extinguisher don't use it for more than 300psi.
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
--Homer Simpson
Add me on ps3: wannafuk, 8/11/11 cant wait
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
i know its rated to 20 barCrna Legija wrote:if thats not a co2 fire extinguisher don't use it for more than 300psi.
Hi!this is my first post.
I have the same fire estinguisher,made from ANAF Group,a french company,
i'm from italy but the product is the same.
During my research i've found that the connection is metrical iso,M30x1,5,you (we) need to find an adapter,from metrical to gas,like this http://www.oleodinamica.org/gas-metrico2.pdf
I have the same fire estinguisher,made from ANAF Group,a french company,
i'm from italy but the product is the same.
During my research i've found that the connection is metrical iso,M30x1,5,you (we) need to find an adapter,from metrical to gas,like this http://www.oleodinamica.org/gas-metrico2.pdf
Last edited by frappu on Tue May 24, 2011 2:30 pm, edited 1 time in total.
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
thx and the link doesnt workfrappu wrote:Hi!this is my first post.
I have the same fire estinguisher,made from ANAF Group,a french company,
i'm from italy but the product is the same.
During my research i've found that the connection is metrical iso,M30x1,5,you (we) need to find an adapter,from metrical to gas,like this http://www.oleodinamica.org/gas-metrico2.pdf.
- streetfire
- Private 4
- Posts: 94
- Joined: Wed May 18, 2011 10:00 am
- Location: the netherlands
still think epoxy is the better way and welcome to the forumfrappu wrote:Sorry,try deleting the dot at the end of the link
- wyz2285
- First Sergeant 2
- Posts: 2385
- Joined: Sat Mar 06, 2010 7:50 am
- Location: Porto, Portugal
- Has thanked: 1 time
- Been thanked: 3 times
- Contact:
That what I did And it worked out fine, but I only used to 20 bar as the bottle won't take more still looking for a 2L CO2 tank .Crna Legija wrote:take it to a hardware store and just test witch fitting fits best, my one was very close to 1/2'' bsp so i just epoxied a 1/2 male fitting in there.