Fire extinguisher connection help

Show us your pneumatic spud gun! Discuss pneumatic (compressed gas) powered potato guns and related accessories. Valve types, actuation, pipe, materials, fittings, compressors, safety, gas choices, and more.
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 10:08 am

does anyone know what what kind of connection i need for a Fire extinguisher tank? its internal size is 28,5 mm the outside is 33,5 mm here's a pic

Image

Image

Image
User avatar
Labtecpower
Sergeant 3
Sergeant 3
Eritrea
Posts: 1297
Joined: Sat Feb 20, 2010 6:38 am
Location: Pyongyang
Has thanked: 5 times
Been thanked: 13 times

Tue May 24, 2011 10:19 am

Kan je een foto maken van de data op de voorkant?
MRR
Specialist 3
Specialist 3
Posts: 361
Joined: Tue Feb 17, 2009 2:29 pm

Tue May 24, 2011 10:51 am

Do you still have the original plug that came with the fire extinguisher?
User avatar
Crna Legija
First Sergeant 2
First Sergeant 2
Posts: 2333
Joined: Sun Jul 20, 2008 5:14 am
Location: australia

Tue May 24, 2011 11:00 am

take it to a hardware store and just test witch fitting fits best, my one was very close to 1/2'' bsp so i just epoxied a 1/2 male fitting in there.

i have tested it to 600psi/41 bar
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson

Add me on ps3: wannafuk, 8/11/11 cant wait
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 12:13 pm

MRR wrote:Do you still have the original plug that came with the fire extinguisher?
yes i have it
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 12:19 pm

Labtecpower wrote:Kan je een foto maken van de data op de voorkant?
ja hoor

Image

Image
MRR
Specialist 3
Specialist 3
Posts: 361
Joined: Tue Feb 17, 2009 2:29 pm

Tue May 24, 2011 12:28 pm

The pipe that reaches from the plug to the bottom of the fe is screwed into it, try if a fitting fits with the threads. If so, cut away the original release valve from the plug and screw the fitting into it from the top.

It worked with my fire extinguisher but there will be some bottlenecking due to the smaller fitting.
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 12:43 pm

MRR wrote:The pipe that reaches from the plug to the bottom of the fe is screwed into it, try if a fitting fits with the threads. If so, cut away the original release valve from the plug and screw the fitting into it from the top.

It worked with my fire extinguisher but there will be some bottlenecking due to the smaller fitting.
will not work well its only from plastic ill think i will epoxy a 22 mm connection in it thanks Crna Legija and thank you all you helpt me get closer to the semi auto qev gun :D
User avatar
Crna Legija
First Sergeant 2
First Sergeant 2
Posts: 2333
Joined: Sun Jul 20, 2008 5:14 am
Location: australia

Tue May 24, 2011 12:47 pm

if thats not a co2 fire extinguisher don't use it for more than 300psi.
'' To alcohol... The cause of, and solution to, all of life's problems.”
--Homer Simpson

Add me on ps3: wannafuk, 8/11/11 cant wait
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 1:09 pm

Crna Legija wrote:if thats not a co2 fire extinguisher don't use it for more than 300psi.
i know its rated to 20 bar
frappu
Private
Private
Posts: 8
Joined: Fri Jan 21, 2011 7:11 am

Tue May 24, 2011 1:24 pm

Hi!this is my first post.
I have the same fire estinguisher,made from ANAF Group,a french company,
i'm from italy but the product is the same.
During my research i've found that the connection is metrical iso,M30x1,5,you (we) need to find an adapter,from metrical to gas,like this http://www.oleodinamica.org/gas-metrico2.pdf
Last edited by frappu on Tue May 24, 2011 2:30 pm, edited 1 time in total.
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 1:55 pm

frappu wrote:Hi!this is my first post.
I have the same fire estinguisher,made from ANAF Group,a french company,
i'm from italy but the product is the same.
During my research i've found that the connection is metrical iso,M30x1,5,you (we) need to find an adapter,from metrical to gas,like this http://www.oleodinamica.org/gas-metrico2.pdf.
thx and the link doesnt work :cry:
frappu
Private
Private
Posts: 8
Joined: Fri Jan 21, 2011 7:11 am

Tue May 24, 2011 2:28 pm

Sorry,try deleting the dot at the end of the link :)
User avatar
streetfire
Private 4
Private 4
Posts: 94
Joined: Wed May 18, 2011 10:00 am
Location: the netherlands

Tue May 24, 2011 2:32 pm

frappu wrote:Sorry,try deleting the dot at the end of the link :)
still think epoxy is the better way and welcome to the forum :D
User avatar
wyz2285
First Sergeant 2
First Sergeant 2
Austria
Posts: 2385
Joined: Sat Mar 06, 2010 7:50 am
Location: Porto, Portugal
Has thanked: 1 time
Been thanked: 3 times
Contact:

Tue May 24, 2011 4:06 pm

Crna Legija wrote:take it to a hardware store and just test witch fitting fits best, my one was very close to 1/2'' bsp so i just epoxied a 1/2 male fitting in there.
That what I did :P And it worked out fine, but I only used to 20 bar as the bottle won't take more :( still looking for a 2L CO2 tank :) .